3000mt Automatic Calibration Magnetic Field Strength Meter Digital Hall Effect Tesla Magnetometer Hgs-106

Lugar de origem Pequim
Marca HUATEC
Certificação ISO, CE, GOST
Número do modelo HGS-106
Quantidade de ordem mínima 1pcs
Detalhes da embalagem Pacote de exportação padrão
Tempo de entrega 1-4days
Termos de pagamento T/T, PayPal, Western Union
Habilidade da fonte 500 por mês.

Contacte-me para amostras e cupons grátis.

Whatsapp:0086 18588475571

WeChat: 0086 18588475571

Skype: sales10@aixton.com

Se tiver alguma preocupação, fornecemos ajuda online 24 horas por dia.

x
Detalhes do produto
Escala de testes 0-300mT~ 3000mt Precisão 0~100mT 1%, 2% acima de 100mT (medido em campo magnético uniforme)
Sensibilidade DC×1:0,00 ~ 300,00mT. 0,01mT DC × 10:0,0 ~ 3000,0mt 0,1mt Campo magnético CA 10-200 Hz
Unidade Alteração da Unidade mT/Gs Tamanho 150 mm × 70 mm × 30 mm
Peso 500g Nome do produto Magnetômetro
Campo magnético medido Campo magnético estático DC, campo magnético dinâmico AC Bateria Bateria seca AA 4pcs
Escolha a função função de manutenção de pico calibração zero ajuste zero automático
Destacar

automatic calibration magnetic field strength meter

,

digital magnetic field strength meter

,

hall effect magnetic field strength meter

Deixe um recado
Descrição de produto

3000mT Automatic Calibration Digital Magnetic Field Strength Meter Hall Effect Tesla Magnetometer HGS-106

 

HGS-106 is a handheld digital gauss meter controlled by single chip microcomputer, which can be used to measure the magnetic induction intensity of dc magnetic field, radiation magnetic field and other magnetic fields. The instrument can be carried around, with a wide range, easy operation and clear LCD display. It has many functions, such as measuring/peak maintaining, MT/GS unit conversion, automatic zero adjustment by push button, 300MT/3000MT range conversion, etc.

 

Main technical indicators

1. Measuring range: 0~300mT~ 3000mt

2. Frequency range: 10Hz~200Hz

3. Accuracy: 0~100mT 1%, 2% above 100mT (measured in uniform magnetic field)

4. Resolution: DC×1:0.00 ~ 300.00mT. 0.01mT

DC× 10:0.0 ~ 3000.0mt 0.1mt

5. Measured magnetic field: dc magnetic field (static magnetic field)

6. Function description: peak maintenance function

Gs (gauss) /mT (millitesla) can be switched freely

7. N/S polarity display during dc measurement. N for positive and S for negative

8. Display button fast automatic zero

9. Ambient temperature: 5℃~40℃

10. Relative humidity: 20%~80% (no condensation)

11. Power supply: four no.5 batteries are externally connected with voltage stabilizing power

12. External size: 150mm (L) ×70mm (W) ×30mm (H)

13. Instrument weight: 450g

14. Display mode: 41/2 LCD

15. Display unit: mT/Gs

16. AC/DC switchable

 

3000mt Automatic Calibration Magnetic Field Strength Meter Digital Hall Effect Tesla Magnetometer Hgs-106 0

 

Operation request:

  1. Magnetic field distribution of material surface
  2. Working magnetic field produced fro some instrument that as iron-removing device,magnet-selecting machine, magnet chuck, magnet spool and demagnetizing coil
  3. Leakage Magnetic iron-surface
  4. Do not use the instrument in unappropriate conditions.
  5. If you find the value of testing were error in the status ofmeasurement,

    you could loosened the handle of the probe to adjust the screw of the resistance tinily.

  6. If don’t ensure that the instrument is operated correctly described below, there would be error or mistake

  7. Don’t attempt to repair, or disassemble, and any reconstruct this instrument.

  8. Use only recommended power accessories.
  9. Don’t connect the terminals of the outer power supply reversely. the inner is plus, the outer is minus.
  10. Don’t drop this instrument or the probe down ground. It’ll be damaged by strong vibration.
  11. Do not allow hands or other objects with dirt to touch the probe.
  12. Avoid using, placing or storing the instrument in places subject to strong sunlight or high temperature, so as to humidity, water, oil, rust air, vibration and others.

3000mt Automatic Calibration Magnetic Field Strength Meter Digital Hall Effect Tesla Magnetometer Hgs-106 13000mt Automatic Calibration Magnetic Field Strength Meter Digital Hall Effect Tesla Magnetometer Hgs-106 23000mt Automatic Calibration Magnetic Field Strength Meter Digital Hall Effect Tesla Magnetometer Hgs-106 3