• HUATEC GROUP CORPORATION
    Prumo
    Tipo da polegada de Astm E114-15 aço carbono 1018 do bloco de teste da calibração Mini Iiw 2
  • HUATEC GROUP CORPORATION
    William
    Tipo da polegada de Astm E114-15 aço carbono 1018 do bloco de teste da calibração Mini Iiw 2
  • HUATEC GROUP CORPORATION
    Tom
    Tipo da polegada de Astm E114-15 aço carbono 1018 do bloco de teste da calibração Mini Iiw 2
  • HUATEC GROUP CORPORATION
    Leão
    Tipo da polegada de Astm E114-15 aço carbono 1018 do bloco de teste da calibração Mini Iiw 2
Pessoa de Contato : Noah
Número de telefone : +8613911115555
Whatsapp : +8613910983110

Digital TOFD Ultrasonic Flaw Detector Negative square wave pulse adjustable TOFD400

Lugar de origem Pequim
Marca HUATEC
Certificação ISO, CE, GOST
Número do modelo TOFD400
Quantidade de ordem mínima 1pcs
Preço 20000-28000USD
Detalhes da embalagem Pacote de exportação padrão
Tempo de entrega 1-4days
Termos de pagamento T/T, PayPal, Western Union
Habilidade da fonte 500 por mês.

Contacte-me para amostras e cupons grátis.

Whatsapp:0086 18588475571

WeChat: 0086 18588475571

Skype: sales10@aixton.com

Se tiver alguma preocupação, fornecemos ajuda online 24 horas por dia.

x
Detalhes do produto
Ecrã Ecrã táctil Borda do pulso <10ns>
Largura do pulso 30 ~ 1000ns ajustável continuamente Exibição de forma de onda ondas de rádio, ondas completas, ondas positivas, ondas negativas
Modo da imagem latente De acordo com as definições do instrumento e o modo de digitalização, exibição de imagem B, D, P, TO
Destacar

digital ultrasonic flaw detector

,

ultrasonic flaw detection

Deixe um recado
Descrição de produto

 

TOFD-400 Ultrasonic Flaw Detector,TOFD technique is to use the work of a new ultrasonic non-destructive testing equipment. It is the high rate of detection of defects in quantitative high positioning accuracy, detection is simple and quick detection efficiency.

With intelligence operations, "one button TOFD" scanning to enable beginners to quickly master, unique touch-screen controls, buttons and the mouse can be used simultaneously, Shuttle controls can be a shuttle in the end, the operation is extremely simple, is the most compact "TOFD" flaw detector, including the battery weighs only 2.25 kg.

 

Main Features:
  1. "One button TOFD" scanning, so that TOFD testing more easier.
  2. Unique touch-screen controls, buttons and the mouse can be used simultaneously, Shuttle controls can be a shuttle in the end, the operation is extremely simple.
  3. The most compact "TOFD" flaw detector, weighing only 2.25 kg with battery
  4. Real-time help tips, ultrasonic flaw detection wave diffraction to solve the traditional single-scan detection limits of the region and non-intuitive.
  5. high-brightness high-resolution true color LCD touch screen.
  6. USB, LAN, SVGA output interface.
  7. Built-in probe position encoder.
  8. large-capacity data storage space.
  9. with A scan, B scan, D-scan and TOFD imaging capabilities.
  10. Real-time A-scan waveform display debugging the instrument is more fast and accurate.
  11. A scan waveform and B, D scanning image synchronized display, so that scanning is more intuitive.
  12. This machine scanning browsing records, and can playback A scan waveform.
  13. Defect size, location and type of accurate analysis.
  14. Manually configure the user-friendly and efficient scanning frame, portable scanning devices instead of manually scanning, detection faster and more accurate.

 

 

 

Main Parameters:

     Pulse type

Negative square wave pulse(adjustable)

Pulse edge

<10ns

Pulse width

30~1000ns  continuously adjustable

Repetition frequency

100~1000Hz adjustable

Detection mode

hardware detection

sampling frequency

100MHz

Frequency band width

0.5~5MHz,2~10MHz,4~15MHz,0.5~20MHz(broadband)

Waveform display

radio-wave, full wave, positive half-wave, negative half-wave

Sound Velocity Range

300~20000m/s

Sound range

5~200μs

Delay range

0~200μs

Trigger Mode

encoder trigger(maximum resolution 0.25mm),time-triggered(Maximum Resolution force 5ms)

Equivalent Input Noise

40×10-9 V/ √Hz

Attenuation Accuracy

< ±1dB/20dB

After the transmit pulse blind

< 2ns

Imaging mode

according to the instrument settings and scanning mode display B sweep, D sweep, P sweep, TOFD imaging

Record method

Complete raw data recording method records (per period "= 5 points)

Scan length

longest single-200m, each piece of 2m can be saved 200pcs

Off-line data analysis

recovery and playback scan A-scan waveforms recorded

Defect size and contour

Thickness / amplitude data statistical analysis

Data report

directly printed check sheet, A scan waveform, B scan images, D scan images, TOFD image

Running Memory

1 G

Available Flash

2 G

Output

LAN,VGA,USB2.0

Display

6.5 "True Color Highlight SVGA640 × 480 pixel high-resolution LCD touch screen

Control

touch-screen views, front panel keypad, Shuttle

Compatible external devices

USB, keyboard, mouse, connected via USB or LAN printer, PC, SVGA external display projector

Power

6600mAH lithium-ion battery, working time "six hours, external 19V adapter

Dimensions

257 (W) × 168 (high) × 64 (thickness) mm (with battery)

Weight

2.25 kg (including battery)