Digital ASTMD2240 / JISK7215 0 - 100HC Shore Durometer HT-6510C

Lugar de origem Pequim
Marca HUATEC
Certificação ISO, CE, GOST
Número do modelo HT-6510C
Quantidade de ordem mínima 1pcs
Detalhes da embalagem Pacote de exportação padrão
Tempo de entrega 1-4days
Termos de pagamento T/T, PayPal, Western Union
Habilidade da fonte 500 por mês.

Contacte-me para amostras e cupons grátis.

Whatsapp:0086 18588475571

WeChat: 0086 18588475571

Skype: sales10@aixton.com

Se tiver alguma preocupação, fornecemos ajuda online 24 horas por dia.

x
Detalhes do produto
Faixa de medição 0-100HC Desvio de medição < 1% H
Fornecimento de energia Bateria AAA (UM-4) de 4x1,5 V Indicador da bateria Indicador de bateria baixa
Destacar

digital shore durometer

,

portable shore durometer

Deixe um recado
Descrição de produto
Digital Shore Durometer Form Hardness Tester Plastic Durometer
 
Product synopsis
Product info: digital durometer for shore hardness testing pocket size model with integrated probe
Test scale: shore hardness
Standards: DIN53505, ASTMD2240, ISO7619, JISK7215
Parameters displayed: hardness result, average value, max. value
Measurement range:0-100HC
Measurement deviation:<1%H
Resolution: 0.1
Auto switch off
With RS232C interface
Operating conditions: 0℃ to 40℃
Power supply: 4x1.5V AAA (UM-4) battery
Battery indicator: low battery indicator
Dimensions: 162x65x38mm

Weight (not including probe):173g

 

Standard accessories:
Main unit
Zero Calibration plate
Carrying case
Instruction Manual
Certificate

CALIBRATION CHECK
To check whether the tester is accurate, just Insert the indenter into the hole of the calibrated test Block. Apply enough force to make firm contact between the top surface of the test block and the presser foot. The reading
should agree with the value stamped on the test block. If not, just carry out Zero calibration and High end calibration.

Zero calibration
Hold the durometer vertically with the point of the indenter hanging in the air, the reading on the display should be '0'. If not, depress the 'ZERO' key to make the tester display '0' .

High end calibration
Just place the indenter onto a flat glass, apply enough force to make firm contact between the glass and the presser foot. The readings on the display should lie between 99.5 and 101. If not, press CAL key to carry out high end calibration.

BATTERY REPLACEMENT
When the battery symbol appears on the display, it is time to replace the batteries.
Slide the Battery Cover away from the tester and remove the batteries.
Install batteries paying careful attention to polarity.

NOTE
Readings below 10HD for Shore D type may be inexact and should not be reported for some materials. Measurements should be made on a Shore A type.
Readings above 90HA for Shore A should be made on a Shore D type durometer